BCI 104
4 COUNTER CHANNELS CONDITIONER TERMINAL BLOCK
FEATURES  

 

  • Conditions 4 counter channels
  • For each channel:

=> 2 AC coupled and setting gain analog inputs

=> Levels ranging from a few mV to ± 40V FS

=> Adjustable trigger threshold

=> 2 "TTL" inputs for control signals

=> 4 differential output generators to counters

  • Test terminals on FRONT panel
  • Terminal block powered by counter boards
    (+ 5V)
  • Direct connections to VME, PC, PCI,…

 

Adas board
 
DESCRIPTION

 

The BCI 104 terminal block conditions 4 counter channels.

Each channel features 2 analog channels and "TTL" channels. Signals from phonic wheels or pulse sensors are discriminated and reshaped before being applied to the counter boards as differential logic signals.

The user can set, for each channel, the measurement amplifier gain and the trigger threshold. The signals obtained are displayed through test terminals.

The BCI 104 terminal block can be powered by the counter boards, and channels can be galvanically isolated from each other.

 

Afaq
9 rue Georges Besse – BP 47 – 78330 FONTENAY LE FLEURY – FRANCE
Tél.:(33) 1 30 58 90 09 - http://www.adas.fr - mail@adas.fr
Afaq
 

 

BCI 104

SPECIFICATIONS (t = 25°C)

TYPE

CONDITIONER TERMINAL BLOCK - 4 COUNTER CHANNELS

PER CHANNEL

 

- Analog inputs

2 AC inputs Ze = 3,16K

- Levels

from some mV to ± 40V FS f(G)

- Gains

G = 1 + 50K / RG

- Comparators

VT = from + 0.5V to + 4.5V

 

Adjustable on the FRONT panel

 

VT = VIN x G

- Input frequency range

1Hz to 40KHz

 

(with : Vin = 1Vcc ; G = 51 ; threshold adjust = 2,5V)

- « TTL » inputs

2

- Differential outputs

4 x RS 422

- Displays

Threshold, signal A, signal B

- Power supply

+ 5V (from the counter board)

- Connection

5-pin 3,81

- Outputs

DB25S (1 for 2 channels) and µD 68 (4 channels)

PRESENTATION

 

- Dimensions in mm (H x W x D)

233.34 x 115 x 30.48

- Fitting

In DIN

ENVIRONMENT

 

- Operating temperature

- 20 °C to + 70°C

- Storage temperature

- 25 °C to + 85 °C

- Relative humidity

90 % (without condensation)

EUROPEAN NORMS  
  EMC - EN 61326 - EN 55011 Class A
  CE Compliance
  ROHS - 2002/95/EC
HOW TO ORDER?

BCI 104

ACCESSORIES

19”/6U enclosure to receive
16 x BCIs series 100

BCI100-RACK

   
1
23/50
 
 
DOCUMENTATION Datasheet - Printable Version
 
 
 